Host Zach Peterson and guest Karen Bernham, founder of EMC United, dissect why the vast majority of electronics fail electromagnetic compatibility (EMC) testing on the first try. They explore systemic gaps in electrical engineering education, outdated advice found in semiconductor data sheets, and the practical realities of debugging layout and shielding issues. The conversation also evaluates the current limitations of simulation and artificial intelligence in predicting EMC compliance.
Find an idea in this conversation · 6 source moments
Searches the ideas on this page, rather than a full transcript.
A few source-linked claims, with plans and opinions kept distinct.
Strategy · Reported state
EMC United
Claim attributed to Karen Bernham. Not independently verified by Sift.
EMC United offers specialized engineering seminars, design reviews, and consulting services focused on electromagnetic compatibility and regulatory compliance for electronic hardware manufacturers.
Claim attributed to Karen Bernham. Not independently verified by Sift.
The tinySA is a low-cost, full-featured spectrum analyzer priced between $100 and $150 utilized by hardware engineers for ad-hoc EMC pre-compliance troubleshooting.
Timestamp links open the original conversation at that moment.
The Engineering Education Gap in EMC
Most electrical engineering programs do not teach electromagnetic compatibility (EMC) because curricula are crowded and focus on trending semiconductor technologies like advanced packaging. Consequently, engineers typically encounter EMC principles only after failing regulatory tests in industry, relying instead on rare institutional centers of excellence or on-the-job training.
Outdated component data sheet advice causes EMC failures
Semiconductor manufacturer data sheets frequently recommend splitting analog and digital ground planes, a practice that made sense in the 1980s with slow clock speeds. In modern high-speed electronics, split ground planes create high-impedance return paths that frequently trigger regulatory compliance failures.
DC-DC converters utilize internal switching operations that generate fundamental frequencies and numerous powerful harmonics. Even when engineers treat a circuit as a DC system, these hidden high-frequency components can dump massive noise into printed circuit boards and cause unexpected test failures at higher frequencies like 120 megahertz.
Radiated emissions drive the majority of initial test failures
Between 60 and 90 percent of commercial electronic units fail their initial EMC compliance testing, with roughly two-thirds of those failures caused by radiated emissions or immunity issues. Unintended antenna effects develop when internal clocks or signals couple onto power cables and enclosures that radiate efficiently at specific frequencies.
Engineers can perform effective pre-compliance troubleshooting using affordable equipment like near-field probes, current probes, and low-cost spectrum analyzers such as the tinySA, which costs between $100 and $150. Using these tools locally helps teams identify major noise sources and run sanity checks before paying thousands of dollars per day at third-party test labs.
Applying artificial intelligence and simulation to EMC compliance is constrained by a severe lack of public training datasets, as most historical test data is proprietary. Furthermore, while signal integrity simulations work well at the micron scale, EMC requires bridging microscopic PCB models with centimeter-to-meter scale enclosures and cables.